submit
CURRENT RATE | 1 eur / Kč |25,07916.12.-22.12.2024
WEEKLY METAL PRICESCuAl
Base price | eur/100 kg |150,00150,00
Current price | eur/100 kg |
892,37316,21
Current recalculation | eur/kg |7,421,66
CURRENT RATE | 1 eur / Kč |25,12 Kč 20.12.2024
DAILY METAL PRICESCuAl
Base price | eur/100 kg |150,00150,00
Current price | eur/100 kg |
877,80310,72
Current recalculation | eur/kg |7,281,61
  • Metallic cables
  • Signal

A-2Y(L)2YV

... x4x0.9 S LG (H45)

1
2
3
4
5
1

Copper wire

2

Core insulation – solid PE

3

Crepe paper

4

Laminated aluminium foil

5

PE outer jacket, black.

Cable is quads stranded in concentric layers

Specification

Dlk. 1.013.109y, Dlk.1.013.110y

Application

» cables are designed for general use in protective equipment
» cables are suitable for placement as in earth or conduits

Environmental conditions

Temperature ranges for laying and assembly –10 °C  to +60 °C
Operation and store temperatures – 25 °C to +60 °C
Permitted minimum bending radius min. 15D
Cable lifetime min. 30 years


D – outside cable diameter

Electrical parameters (20 °C)

Conductor diametermm0.9
Max. loop resistanceΩ/km56.6
Insulation resistance min.GΩ.km10
Mutual capacitancenF/km45
Effective test voltage wire/wire at 50 HzV2500
Effective test voltage wire/shield at 50 HzV2500
Operating voltage Vss600
Wire/core diameter H45 0.9/1.8 mm
Number of units External diameter [mm] Net weight [kg/km] Standard production length [m]
1 10.0 100 1,000
3 15.0 190 1,000
5 17.0 290 1,000
7 19.0 360 1,000
10 22.0 490 1,000
14 25.0 640 1,000
20 28.0 860 1,000
30 34.0 1,240 1,000
40 38.0 1,610 1,000