submit
CURRENT RATE | 1 eur / Kč |25,07916.12.-22.12.2024
WEEKLY METAL PRICESCuAl
Base price | eur/100 kg |150,00150,00
Current price | eur/100 kg |
892,37316,21
Current recalculation | eur/kg |7,421,66
CURRENT RATE | 1 eur / Kč |25,12 Kč 20.12.2024
DAILY METAL PRICESCuAl
Base price | eur/100 kg |150,00150,00
Current price | eur/100 kg |
877,80310,72
Current recalculation | eur/kg |7,281,61
  • Metallic cables
  • Telecommunication

A-02Y(L)2Y

...x2x0.5 ST III BD (H42)

1
2
3
4
5
1

Copper wire

2

Core insulation – foam skin PE

3

Crepe paper

4

Laminated aluminium foil

5

PE outer jacket, black

Transmission element – star quads twisted to unit.

Specification

Technical Agreement

Application

» connection cables in Local Area Networks and in private branch exchanges for telephony and signal transfer
» suitable for placement as underground and conduit cables

Environmental conditions

Temperature ranges for laying and assembly –10 °C  to +60 °C
Operation and store temperatures – 40 °C to +70 °C
Permitted minimum bending radius min. 10D
Cable lifetime min. 30 years


D – outside cable diameter

Rings identify the individual conductors

Pair 1 a
b
Pair 2 a
b

Electrical parameters (20 °C)

Conductor diametermm0.5
Max. loop resistanceΩ/km196.0
Insulation resistance min.GΩ.km5
Mutual capacitancenF/km42
Effective test voltage wire/wire at 50 HzTest voltage wire/wire at 50 HzV500
Effective test voltage wire/shield at 50 HzV2,000
Operating voltageVss150
Wire/core diameter H42 0.5/0.8 mm
Number of units External diameter [mm] Net weight [kg/km] Standard production length [m]
2 9.4 70 2,000
4 11.1 95 2,000
6 11.6 105 2,000
10 12.5 120 2,000
20 15.1 180 2,000
30 16.8 220 2,000
40 18.1 255 2,000
50 19.1 270 2,000
70 21.2 310 2,000
100 23.9 580 2,000
150 28.3 750 2,000
200 31.4 950 2,000
250 34.0 1,200 2,000
300 36.8 1,350 2,000
400 39.0 1,400 2,000
500 41.1 1,750 1,000
600 44.9 1,900 1,000
700 49.2 2,200 1,000
800 52.9 2,620 1,000
1000 63.7 4,250 500

Other telecommunication cables